Pressure gauges to EN 837: accuracy class, scale range, safety case and accessories

26 October 2026 · 9 min read · EN 837-1, EN 837-2, EN 837-3

In short

The humble pressure gauge is the instrument operators trust most, because it needs no power and no screen. It is also often specified by copying a line from the last project. EN 837 gives clear rules, and following them avoids gauges that are unreadable, inaccurate or dangerous when they fail.

Where this matters

How it works

Most gauges use a Bourdon tube: a curved, flattened tube that straightens slightly under pressure and drives the pointer through a gear movement (EN 837-1). For low pressures and corrosive fluids, diaphragm (plate) gauges are used (EN 837-3), and for very low gas pressures, capsule gauges.

Accuracy class

maximum error = class % × full-scale value
ClassError on 0–16 barTypical use
0.6±0.096 barTest gauges
1.0±0.16 barProcess gauges, 100 mm and larger
1.6±0.26 barGeneral service
2.5±0.40 barSmall dials, utilities

The error is fixed in bar, so it is a larger share of a small reading. This is one reason not to oversize the scale.

What the standards and practice say

Accessories

AccessoryWhen
Siphon (pigtail or U-tube)Steam and hot vapours: holds a condensate seal so hot steam doesn't reach the tube
Snubber or pulsation damperPump discharge, reciprocating compressors, hydraulic systems
Overpressure protectorWhere pressure can exceed the scale, e.g. a low-range gauge on a higher-pressure line
Diaphragm sealCorrosive, viscous or clogging fluids (article 2.4)
Gauge valve or 2-valve manifoldIsolation, venting and testing without a shutdown

Worked example: a pump discharge gauge

InputValue
Normal / maximum pressure6 / 8 barg, pulsating
FluidWater at 40 °C
Accuracy neededTo about ±0.2 bar

Step 1, scale. The pressure is pulsating, so the working value should be at most ⅔ of full scale. For 8 barg maximum, full scale must be at least 8 / (2/3) = 12 bar. The next standard scale is 0–16 bar. On a 0–10 bar dial, 8 barg would be at 80 %, too high for pulsating service.

Step 2, class. Class 1.0 on 0–16 bar gives ±0.16 bar. That meets ±0.2 bar. Class 1.6 (±0.26 bar) would not.

Step 3, case and accessories. Water at 8 barg does not need an S3 case on a strict reading, but many specifications require it for all process gauges. Pulsation calls for a liquid-filled case and a snubber.

OptionMax atErrorResult
0–10 bar, class 1.680 %±0.16 barToo close to full scale for pulsation
0–16 bar, class 1.650 %±0.26 barAccuracy not met
0–16 bar, class 1.0, filled, snubber50 %±0.16 barMeets both

What this example shows

When it fails: the fixes in order

  1. A shaking pointer or worn movement: fit a snubber and a liquid-filled case. Check the mounting is not on a vibrating pipe.
  2. Reading stuck after a steam event: fit a siphon and fill it with water before commissioning.
  3. Zero shifted: the gauge was over-ranged. Use a higher scale or fit an overpressure protector.
  4. Blocked or corroded: fit a diaphragm seal or change the wetted material.

Common mistakes

Checklist

Quick reference

Further reading

The selection rules follow EN 837-2 as commonly applied. Confirm against the edition used by your project and the company's gauge specification. EN is named for identification only.